XStream"燨EM燫F燤odule?燩roduct燤anual爒5.x00燵2006.02.24]?/DIV>
LH (Wake-up Initializer Timer) Command
AT Command: ATLH
Binary Command: 0x0C (12 decimal)
<Sleep (Low Power)> Set/Read the amount of
time during which the RF initializer is sent. When
receiving modules are put into Cyclic Sleep Mode,
they power-down after a period of inactivity
[specified by ST (Time before Sleep) Command]
and will periodically awaken and listen for
transmitted data. In order for the receiving
modules to remain awake, they must detect
~35ms of the wake-up initializer.
Parameter Range:   0  0xFF
 
[x 100 milliseconds]
Default Parameter Value: 1
Number of bytes returned: 1
Related Commands: HT (Time before Wake-up
Initializer), SM (Sleep Mode), ST (Time before
Sleep)
LH Command must be used whenever a receiver is operating in Cyclic Sleep Mode. This lengthens
the Wake-up Initializer to a specific amount of time (in tenths of a second). The Wake-up
Initializer Time must be longer than the cyclic sleep time that is determined by SM (Sleep Mode)
Command. If the wake-up initializer time were less than the Cyclic Sleep interval, the connection
would be at risk of missing the wake-up initializer transmission.
Refer to the figures in the Sleep Mode sections [p13] to view correct and incorrect configuration
diagrams. The images help visualize the importance that the LH value be greater than the SM cyclic
sleep value.
MD (RF Mode) Command
AT Command: ATMD
Binary Command: 0x32 (50 decimal)
Parameter Range:   0  4
 
Parameter
Configuration
 
0
Peer-to-Peer
(transparent operation)
 
1
Multi-Stream Base
 
2
Multi-Stream Remote
 
3
Repeater & End Node
 
4
End Node
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
CM (Connection Message), DC (Disconnect)
Minimum Firmware Version Required: 4.30
<Networking & Security> The MD command is
used to select/read the RF Mode (Peer-to-peer,
Multi-Stream or Repeater Modes) of the module.
Multi-Streaming Mode enables exclusive
connections in point-to-multipoint networks.
Refer to the Multi-Streaming Mode section [p43]
for more information regarding how these
parameter values affect other parameter values.
Repeater Mode enables longer range via an
intermediary module. When MD=3, the module
will act as a store and forward repeater. Any
packets not addressed to this node will be
repeated. A Repeater End Node (MD=4) handles
repeated messages, but will not forward the data
over-the-air. Refer to the Repeater Mode section
[p38] for more information.
 
MK (Address Mask) Command
牋牘?006燤axStream,營nc.燙onfidential燼nd燩roprietary?/DIV>
27?/DIV>
<Networking & Security> MK Command is used
to set/read the address mask of the module.
All data packets contain the destination address
(DT Parameter) of the transmitting module.
When an RF data packet is received, the
transmitters destination address is logically
ANDed (bitwise) with the Address Mask of the
receiver. The resulting value must match the
destination address or the address mask of the
receiver for the packet to be received and sent
out the module DO serial port. If the ANDed
value does not match either the destination address or the address mask of the receiver, the
packet is discarded. (All 0 values are treated as irrelevant values and are ignored.)
AT Command: ATMK
Binary Command: 0x12 (18 decimal)
Parameter Range:   0  0xFFFF
Default Parameter Value: 0xFFFF
(Destination address (DT parameter) of the
transmitting module must exactly match the
destination address of the receiving module.)
Number of bytes returned: 2
Related Commands: DT (Destination Address),
HP (Hopping Channel), ID (Module VID), MY
(Source Address)
Refer to the Addressing Options section [p36] for more information.
相关PDF资料
XIB-R BOARD INTERFACE RS232/485
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
02110102-000 SNSR TILT RATIO 60DEG 500MA FLNG
1-5209285-2 FOPC BOA 12DB FC/UPC BP SM
2-1693560-0 BOA 20DB LC/UPC BB
517SS16 MAGNETIC SENSORS BIPOLAR ICS
相关代理商/技术参数
XIB-R 功能描述:界面模块 RS-232/485 interface 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIB-U 功能描述:界面模块 USB interface board 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIC25040 制造商:XIC 功能描述:25040 24HR '6
XILINXPWR-079 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-080 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-081 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-082 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-083 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V